LOVATO
Näitan 1–24 tulemust 31-st
-
-
Taimerid
Nivoo kontrollirelee 1 funkts. 1CO 2,5-100kOomi 24-230VAC/DC
Tootja ID: LVM25240Modular level control relays for conductive liquids. Automatic resetting.
Use with 3 sensing electrodes, MIN, MAX and COM (not included).
2.5-50kOhm adjustable sensitivity.
Programming selector for emptying or filling function with fail-safe operation.
Double insulation between each supply, electrode and output relay circuit.
Adjustable probe signal delay: 1-10s.
Adjustable pump start delay: 0-300s.
Green LED indicator for power on. Red LED indicator for output relay state.
Modular DIN 43880 housing, 3 modules.
Degree of protection: IP40 on front (only when mounted in housing or electric board with IP40); IP20 on terminals.SKU: 022887 -
Taimerid
Nivoo elektrood 100mm max.60°C Lovato
Tootja ID: 11SN1A single pole level electrode for conductive liquids.
Used for level control in wells or storage tanks.
It comprises an AISI 303 stainless steel probe, a plastic (PPOX) holder and a cable gland.
The external cable diameter must be 2.5 to 6mm to warrant perfect sealing of the PG7 gland.
Maximum operating temperature: +60°C.SKU: 022886 -
Taimerid
Faasi kadu/järiestuse kontrollirelee 1mod. 208-440VAC
Tootja ID: PMV10A440- Three-phase system without neutral control
- 1 relay output with 1 changeover contact, rated 8A at 250VAC
- Phase loss for voltage <70% with instantaneous tripping, automatic reset in 0.5s and fixed 5% hysteresis.
- Phase sequence controlled at unit power up.
SKU: 020446 -
Taimerid
Aegrelee 1CO 10 functions 0,1sek-240h 12-240V AC/DC
Tootja ID: TMM1– Electronic time relay, multifunction, multiscale, multivoltage
– Enabling input
– 1 relay output with 1 changeover contact (SPDT)
– Selectable functions: (a) On delay; delay on make with start at relay energising. (b) Pulse on relay energising with start when energised. (c) Flasher starting with OFF interval. Equal timing recycle. (d) Flasher starting with ON interval. Equal timing recycle. (e) Off delay; relay energising at external contact closing with start on break. (f) Pulse on relay energising with start on external contact closing. (g) Pulse on relay energising with start on external contact opening. (h) On-off delay. Delay on make, with start at external contact closing, and delay at break, with start at external contact opening. (i) Internal ON/OFF trigger with relay contact closing or operating at each closing of an external contact. (j) Pulse generator, unequal timing recycle; starting with OFF pulse time and 0.5s ON pulse.
– Delay time adjustable on front by rotary switch: 10…100%
– Green LED indicator for power on
– Red LED indicator for relay state; flashing for delay and steady when relay energised
– Modular DIN 43880 housing, 1 module suitable for fixing on 35mm DIN rail (IEC/EN 60715)
– IEC degree of protection: IP40 on front (only when mounted in housing or electric board with IP40); IP20 on terminals.SKU: 017576